Our product range includes a wide range of feeder pillar with horizontal switch fuse unit and feeder monitoring system.

Feeder Pillar with Horizontal Switch Fuse Unit

Feeder Pillar with Horizontal Switch Fuse Unit
  • Feeder Pillar with Horizontal Switch Fuse Unit
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandRaychem RPG
IP RatingIP54 and IP55
FuseEasy and safe connection & disconnection of fuse
FeaturesEasy voltage measurement,comfortable access with standard voltage testers
Current Rating400Ato 1000A
Short circuit capacityUp to 50kA,1 Sec.

The NH Fuse-Switches, horizontal design series offers plant designers and switchgear manufacturers a modular system with reliable and easy-to install switching devices. The feeder pillar with horizontal SFU optimizes space and reduces overall height of the system for special applications in power distribution utilities & industrial segment.

Features & Advantages

- Current rating 100A to 630A
- Uniform installation depth
- Offer perfect protection against accidental contact for ultimate safety and visual appeal of the power distribution system
- Easy voltage measurement, Comfortable access with standard voltage testers
- Fully Insulated & touch proof
- Easy and safe connection & disconnection of fuse
- The wide range of accessories offers a multitude of modification and upgrade options to suit any need
Request
Callback


Additional Information:

  • Item Code: HSFU
Yes! I am Interested
View PDF

Feeder Monitoring System

Feeder Monitoring System
  • Feeder Monitoring System
Ask For Price
Product Price :Get Latest Price
The substation Total Demand Monitor is easy to install (30-45 minutes), versatile and configurable metrology system. The total demand of the substation or feeder is calculated by the summation of the feeder loads and all loading parameters are measured. The system may be configured to measure transformer output and feeders by using Rogowski coils. Busbar voltage phase to phase angles may also be measured for the 3 phases. Working in conjunction with RTU, the data is transmitted to a central server over GPRS.

Advantages for network engineer & managers

  • Continuous substation monitoring and real time data optimized decision making
  • No calibration, no maintenance required
  • Reduce losses, improve efficiency and cost of network
  • Increase customer quality of service
  • Integrate with current/future Smart Grid systems

Features

  • Ease of Installation plug and play interface for both current sensors and voltage inputs (Live fit)
  • Maximum no. of 6 LV feeders per metrology unit. Capable of daisy chaining up to 2 metrology units with a single using only 1 RTU
  • Additional inputs for 2 temperature sensors
  • 3 Phase + Neutral Current measured using Rogowski coils per feeder
  • Voltage data aggregation of Min, Max, Average and RMS values
  • LCD on RTU can be used to display Modbus parameters
  • Configurable/programmable Alarms for all parameters
  • Solid State Data Storage as backup
  • Lockable case with overall dimensions of 425mm x 300mm x180mm
  • Ingress Protection IP65 (EN60529) and Impact Resistance IK06 (EN62262)